32-8 Flow
|
Controlling of:
Beer pumps, Post mix, Premix, Fruit juice machine, 1 handdouche with 7 products, 2 doses / product, Non drip balk (1 node for the Non Drip), Speedrail (1 node for the speedrail) ... Or a combination of these
|
|
|
|
|
Datasheet - 32-8 Flow.pdf (291Kb)
Manual - Universal node 32-8 Flow.pdf (667Kb)
|
|
|
|
ABC
|
Features :
To dose alcohol bottles
Possible tap styles: Single or continuous tap
7 products with 3 doses
Can power the network
|
|
|
|
|
Datasheet - Alcohol Bottel Control - ABC.pdf (219Kb)
Manual - Alcohol Bottle Control - ABC.pdf (702Kb)
ABC pourers sheet.pdf (16Kb)
|
|
|
|

ABC-TAG
|
Features :
To dose alcohol bottles
Possible tap styles: Single or continuous tap
Endless amount of products with each 3 doses
Can power the network
|
|
|
| |
Datasheet - Tag Alcohol Bottle Control - ABC-Tag.pdf (420Kb)
Manual - Tag Alcohol Bottle Control - ABC -Tag.pdf (1.153Kb)
|
|
|
|

8 I/O
|
Features :
Controlling same devices as 32-8
Able to dose on time and on flow
Does not need a Dino PC. The 8IO works as a stand-alone device
8 outputs with 4 doses
Serial port to connect printer
Can power the network
Manual operations possible (in case of electronic failure)
|
|
|
|
|
Datasheet - 8IO.pdf (156Kb)
Manual - 8IO.pdf (1845Kb)
|
|
|
|

Echelon KB
|
Features:
Reading tag cards.
Entering products line the payment system
Printing the ticket
Able to increase the products by using a Shift key?
Able to open a Bar (like a regular tag reader)
Can be used as a cocktail machine input device (with special eeprom)
|
|
|
|
|
Datasheet - Echelon Keyboard.pdf (110Kb)
Manual - Echelon Keyboard.pdf (476Kb)
Manual - Cocktail Keyboard + Node.pdf (881Kb)
|
|
|
|

Lafet
|
Features :
Counting the number of bottles (units) token from a refrigerator.
Up to 5 weight sensors
Maximal load of 100kg (220lb)
Controlling the doors with reed contacts
External alarm (12V DC)
Can not power the network
|
|
|
|
|
Datasheet - Weight controller.pdf (110Kb)
Manual - Weight controller.pdf (595Kb)
|
|
|
|

Fifo
|
Features :
Up to 6 products
Controlling by infra-red gate
Counting the number of bottles (units) token from a fifo refrigerator.
Internal alarm
Time detection for the infrared beam. If a person keeps his
hand longer than that time in the beam the alarm will
sound. (Wait)
Settable timeout that a persons hand can go out of the
infrared beam before the Fifo will count the action.
(TimeOut)
Can power the network
|
|
|
|
|
Datasheet - FiFo.pdf (111Kb)
Manual - Fifo.pdf (515Kb)
|
|
|
|

TAG Reader
|
Features :
Reading tag cards.
Text position on the graphical tag reader can be turned by
software.
Version with card clip available
Version with card insert (Yellow insert) available
Can not power the network
|
|
|
| |
Datasheet - Tag Reader.pdf (84Kb)
Manual - Tag Reader.pdf (206Kb)
|
|
|
|

24-in
|
Controlling of:
Tourniquet
Coffee machines
Chocolate milk machines
Reading inputs
…
24 inputs
4 outputs
Can not power the network
|
|
|
| |
Datasheet - Inputnode - 24.pdf (114Kb)
Manual - Inputnode - 24.pdf (659Kb)
|
|
|
|

Serial
|
Controlling of:
Coffee machines (CSI interface: baud 9600)
32 products
Can not power the network
|
|
|
| |
Datasheet - Serial node.pdf (162Kb)
Manual - Serial node.pdf (617Kb)
|
|
|
|

Barmatic
|
Controlling of: Barmatic valves
Possible tap styles: 8 products
Can be build inside the Barmatic
Can not power the network
|
|
|
| |
Datasheet - Barmatic.pdf (161Kb)
Manual - Barmatic.pdf (529Kb)
|
|
|
|

Mini Max
|
Controlling of: Beer pumps, Postmix, Premix, Fruit juice machine..or a combination of these
Possible tap styles: Tap just once, Continuous tap, Split tap (prevents over foaming)
Possible tap kinds: Normal tap, Freeflow (manual tap, register per entity), Stop (stop the tap or start a top up), Foam
2 outputs with 4 doses
Can power the network
Manual operations possible (in case of electronic failure)
|
|
|
| |
Datasheet - MiniMax.pdf (206Kb)
Manual - MiniMax.pdf (629Kb)
|
|
|
|

Foam Detector
|
Features :
Detection if the beer tank is empty and stops a 32-8, 32-8 flow or MiniMax from tapping.
Up to 6 foam detectors
Version with 2 foam detectors
Version with 4 foam detectors
Version with 6 foam detectors
Simple recalibration by pressing the Reset key
Clean mode, to clean the pipes
Visual reproduction of the situation with LEDs. This at the node and at the bar.
Can not power the network
|
|
|
| |
Datasheet - Foam detector.pdf (283Kb)
Manual - Fob detector.pdf (232Kb)
|
|
|
|
Fast Flow
|
Controlling of:
Fastflow valves
1 product with 4 doses
Easy to set in calibration mode (for technicians of the soda company).
Easy connection between FastFlow and front panel.
Powered by the FastFlow valve
Can not power the network
|
|
|
| |
Datasheet - Fastflow.pdf (191Kb)
Manual - Fastflow.pdf(524Kb)
|
|
|
|

Flow 2000
|
Features :
Counting the number of flow pulses tapped.
Calculates the tapped volume by the calibration value and the counted flow pulses.
Up to 4 flow meters
Can hold the beer when there is no valid card in the reader. (connect a normal closes valve to the beer pipe)
Can power the network
|
|
|
| |
Datasheet - Flow 2000.pdf (290Kb)
Manual - Flow 2000.pdf (534Kb)
|
|
|
|

Mega Flow
|
Features :
Counting the number of flow pulses tapped.
Calculates the tapped volume by the calibration value and the counted flow pulses.
Up to 16 flow meters
Can power the network
|
|
|
| |
Datasheet - MegaFlow.pdf (204Kb)
Manual - MegFlow.pdf (572Kb)
|
|
|
|
MDB
|
Controlling of:
MDB vending machines
MDB node is master
32 products
Can not power the network
|
|
|
| |
Datasheet - MDB node.pdf (165Kb)
Manual - MDB node.pdf (632Kb)
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|